top of page
Date
Name
Affiliation
Other Observers
Instrument
Hours Observed
Hours Lost
Reason
Observing Program
09/16/2025
William Keel
University of Alabama
Nobody
ARC CCD
0
9
Clouds
Clouds. Brighter stripes in long darks suggest chip may still be recovering from very bright objects, or may have nonuniform temperature?
09/11/2025
Xianming Han
Butler University
none
CCD
0
10
Humidity
none
09/10/2025
Xianming Han
Butler University
none
CCD
0.5
9.5
Humidity
active star.
09/08/2025
Alexandra Yep
Agnes Scott College
Mai Le, Gary Henson
Spectrograph
3
0
Software/Control PC Issues
Pretty good for the most part, focusers all working well, got some decent spectra of bright stars. However, the autoguider in X-stage Guider is not working! Isn't receiving anything from Maxim DL into X and Y Corrections, they're just stuck at 0. So, we had to guide manually using ACE SoftPad. Okay for short exposures, wouldn't be okay for long ones. Please fix.
09/07/2025
Gary Henson
ETSU
none
Spectrograph
7.5
0
Software/Control PC Issues
Was able to observe, but ARC ccd stopped communication during pre-sunset test exposures and would not re-establish communication with computer. ACE software also not receiving corrections from Maxim guider software. Asked ACE to look into both issues.
09/06/2025
Robert
Ball State University
none
arc
0
10
Clouds
clouds and high humidity prevented opening for the evening.
09/05/2025
Martha A. Leake
Valdosta State University
none
CCD
0
9
Clouds
Conditions look too likely for thunderstorms and clouds, although the "Domes closed" warning has been removed. Forecast indicates 40-50% Thunder storms and showers. Not opening tonight and filing report early.
09/02/2025
Gary Henson
ETSU
none
spectrograph
0
9
Clouds
NOTE: Leake report for 9/2 actually for 9/1 civil date. Clouds, light rain, humidity into early AM hours, never opened. Did set focus for spectrum and fiber for spectrograph and verified calibration lamp positions.
09/02/2025
Martha A Leake
Valdosta State University
none
ccd
0
10
Clouds
Did not open: "Domes closed because of threatening clouds" at 10 pm MST (1:00 am EDT) Some precipitation in the area and up to 20% probability this evening and morning. Asteroid light curves will wait. Looks like similar weather all week.
08/30/2025
William Keel
University of Alabama
DragonV\Con Live Astronomy
ARC CCD
5
0
No problems to report
Outreach objects, Focus 532500 (became unstable late). Focus close to starting value after monsoon shutdown. QSI camera could not be contacted by MaximDL.
08/29/2025
William Keel
University of Alabama
DragonCon Live Astronomy
ARC CCD
0
4
Other
After Peter fixed dome and restored connection to ARC CCD, weirdness in post-monsoon grogginess remained, Zenith twilight sky (where Axis camera confirmed mirror cover was open and telescope pointed out open dome) show a single bright spot with extensions along x and y axes, plus scattered light artifacts. Doesn't look like shutter or filter (initialized both filter wheels). Thought it might be spectrograph pickoff in the beam - it never connected to the controller when I tried selecting its instrument tab.
07/06/2025
Todd Vaccaro
Ball State University
n/a
ARC
0
7
Equipment Failure
EB and nova follow up denied mostly due to dome and ARC ccd not funcitioning enough to open (dome not showing position/open status and ccd warm), which is possibly due to extended power outages caused by storms and no one around to personally restart things. Only an hour or two was effectively lost since high humidity kept things shut most of the night.
bottom of page