Date
Name
Affiliation
Other Observers
Instrument
Hours Observed
Hours Lost
Reason
Observing Program
01/18/2021
Núria Torres-Albà
Clemson University
Dieter Hartmann
-
8
0
No problems to report
Clemson University Blazar Observations. No problems to report.
01/14/2021
Ken Watanabe
FGCU
Nick Rimbert
None
0
9
Connection Issues
Not able to keep connection using cisco vpn on win 10. Not other way to connect?.
01/08/2021
Ken Rumstay
VSU
None
CCD camera
9
0
No problems to report
AGN monitoring program No problems to report. Telescope tends to point north of target, as noted by Bill Keel. Optimum focus 131000 at 12 Celsius. CCD temperature was -28 Celsius at start; it cooled to -30 within an hour and remained there.
01/07/2021
William Keel
University of Alabama
3 cats
FLI CCD
8.5
0
No problems to report
Test drive, galaxies in H-alpha. Focus=133000. Even after initialization, the guider x-stage has limited movement; to the west it can’t quite reach W1. The NSEW directions are 180 degrees rotated from their previous directions; +x is to the east and +y to the north. The guider settings for x and y speed and angle are 1,1,0 (sign changes on the speeds from previous values). The guider focus is close to 0. Guiding works well; in some parts of the sky there were oscillations of 1-2” lasting several minutes, as if the slow-motion controls didn’t have enough authority in those locations. There was one complete guide failure where the stars wandered around by 30 arcseconds. Evening twilight flats showed a very large elliptical “Eye of Sauron” pattern which is new; bright in some filters and dark in others. There are also three new narrow features looking almost like scratches. I’ll check in the morning to see how reproducible these flat-field features are and compare sensitivities using Landolt standards with the latest pre-shutdown values. The cooler is struggling even with set point -30 C - the reported value ranged from -22 to -28.
05/27/2020
Xianming Han
Butler University
none
CCD
7
1.5
Software/Control PC Issues
Observed eclipsing binary. 1. The ACE control cabinet needed rebooting at the beginning of the night. 2. The FWHM was spreading too widely for the same focus position, so that the auto focusing was confused about what is the best focus position. Solution: narrow down the search range. 3. Telescope lost tracking about 2 hours before the end of the night. Once that was fixed, the dome lost tracking It turns out the dome does not move at all, not even manually. So closed the telescope.