top of page
Date | Name | Affiliation | Other Observers | Instrument | Hrs Observed | Hrs Lost | Reason | Observing Program |
|---|---|---|---|---|---|---|---|---|
07/27/2026 | Tom Rutherford | ETSU | None | CCD | 8 | 0 | No problems to report | When I first logged on, the dome was stuck on "opening." I eventually rebooted the telescope and CCD computers and had no issues for the remainder of the night. M31, delta Scuti star. |
07/25/2026 | Alba Rico | Clemson University | Dieter Hartmann | JKT | 6 | 2 | Software/Control PC Issues | Clemson AGN project.
Hours lost due to tracking/software issues. |
07/25/2026 | Ken Watanabe | FLorida Gulf Coast University | Jonathan, Evelyn | CCD | 6 | 2 | Equipment Failure | A couple problems occurred, but all were solved. Manual dome azimuth control didn't work. Dome Azimuth drive power cycle fixed this (turning on and off for a minute). Camera appeared to disconnect during flat (Image fully white). Quick restart fixed this. Telescope appeared to stop tracking (Stars streaked across entire image) which led to telescope unable to slew due to equipment failure. Full restart fixed this issue. Dome closed, powered off and night lights on. Mirror cover closed and telescope parked. |
07/24/2026 | Kurtis Williams | ETAMU | Billy Quarles, Ivan Penuelas, Raven Powers | Andor CCD | 7.5 | 0.5 | Software/Control PC Issues | First target was an eclipsing binary which was observed for 4 hours. We tried using the exposure sequence for calibrations and it was changing filter wheel 1 when the sequence only specified a filter wheel 2 switch. Switched to a rotating white dwarf target and had issues with the filter wheel getting stuck. Full reset of everything fixed this problem. Dome stopped tracking and software crashed 30 minutes later but another reset cleared all problems. No further issues. |
07/22/2026 | Todd Hillwig | Valparaiso University | None | Andor CCD | 10 | 0 | No problems to report | Narrow band imaging search for fossil planetary nebulae. |
07/20/2026 | Tom Rutherford | ETSU | None | CCD | 8 | 0 | No problems to report | No problems, although I could not get the autoguider to respond. Also, at some point during the night, the mirror cover started flashing "opening" even though it showed "open" earlier. Variable star, M31. |
07/18/2026 | Ken Rumstay | VSU (Emeritus) | None | Andor CCD camera | 8 | 1 | Software/Control PC Issues | AGN variability program. Performed a full reset at start of night, and again a couple hours later when telescope stopped tracking. No other issues. |
07/17/2026 | Todd Vaccaro | Ball State University | n/a | Andor | 7 | 1 | Equipment Failure | Nova and EB. Twice the dome failed to track, once (again like earlier in the month) near AZ 0, like it had trouble going from E to W across due N, but then again later with different target in SW but only after I noticed that the dome was showing as AJAR! and then it started vignetting and upon trying to unlink/link dome and slew to target (with no real tele motion needed, though it worked earlier) it failed; I tried to home the dome and ACE crashed, so I did a full reset like before and closed up early. There was also a Warwick telescope that appeared to have its lights on with an open dome for most of the night. The night seemed to have a haze but humidity was always low and clouds were at lower altitudes. The tele mirror cover and dome appeared to close in ACE, though it was too dark to verify dome closure. I tried to manually move the dome to the N so that I could see it closed in one of the web cams, but it wouldn't move. I noticed that doing a full reset also powered back on the dome Az, which explains the failure to manually move dome, so I turned them both off and then was able to move the dome, but couldn't see an updated web cam image to verify dome closed. |
07/17/2026 | Billy Quarles | ETAMU | Caysen Mayo | CCD | 5 | 0 | Software/Control PC Issues | Observed asteroid, no issues with data collection. At one point in the night, I was not able to close the dome (telescope software would just minimize instead of closing the dome when icon was clicked) so I had to restart. Once I did a full restart, I was able to close dome & mirrors. |
07/15/2026 | William Keel | University of Alabama | 4 cats | Andor CCD | 9 | 0 | No problems to report | Excellent night on AGN-ionized clouds. Telescope coordinates showed -- at connection; cycled power on ACE cabinet and camera/mirror support outlets (which seems to have fixed guider connection). Guider x-stage is working again. Found night light on when focusing on standard stars at beginning of night. Focus 100656; guider focus 0. Used guider with 1x1 binning out of caution since it has had issues recently. |
07/13/2026 | Xianming Han | Butler University | Betuel Paz | ccd | 8.5 | 0 | No problems to report | eclipsing binaries |
07/12/2026 | Xianming Han | Butler University | Betuel Paz | ccd | 4 | 4 | Software/Control PC Issues | could not slew the telescope. Rebooted ACE cabinet afterwards to fix the problem |
bottom of page