Date | Name | Affiliation | Other Observers | Instrument | Hrs Observed | Hrs Lost | Reason | Observing Program |
|---|---|---|---|---|---|---|---|---|
05/14/2021 | Stefan Geier | GRANTECAN / IAC | none | ARC CCD Camera | 8 | 0.3 | Equipment Failure | At the beginning of the night (around the end of astronomical twilight), the telescope suddenly stopped tracking, and when I tried to point again, it failed with a message about an "equipment error". I then did the "full restart" which is described in the readme, and after that, it worked fine again. |
05/11/2021 | Chloe Nelson | Embry-Riddle Aeronautical University - Daytona Beach, FL | Stephen Gillam | Andor Camera | 11 | 2 | Equipment Failure | ROAP Stars <3
We conducted two "azimuth recycles" (found in the notes) during our observation and one "full restart" (also found in the notes). |
05/12/2021 | Chloe Nelson | Embry-Riddle Aeronautical University - Daytona Beach, FL | Stephen Gillam and Kiara Richardson | Andor Camera | 13 | 0 | No problems to report | ROAP Stars
No problems :)) |
05/13/2021 | Chloe Nelson | Embry-Riddle Aeronautical University - Daytona Beach, FL | Stephen Gillam and Kiara Richardson | Andor Camera | 13 hours | none | No problems to report | ROAP Stars
No problems :) |
05/09/2021 | James Webb | Florida International University | Viviana Arroyave, Luna Webb, Sparkle Webb | CCD | 9 | 0 | Other | blazar microvriability
Wasn't able to park telesope in recommended position. It kept telling me that location was out of limits, so I left it zenith parked.
|
05/09/2021 | Todd Vaccaro | BSU | None | Andor CCD | 7 | 3.5 | Humidity | Eclipsing binary; ACE crashed twice, but simple restart seemed to fix, but I had to reset most observing parameters; Humidity over 80% during last 3 hrs and never dropped to reopen. |
05/07/2021 | Ross Silver | Clemson University | Dieter Hartmann | CCD | 9 | 0 | No problems to report | Photometric redshift of blazars. |
05/05/2021 | Ed Albin | Agnes Scott College | Amy Lovell | CCD | 9 | 1 | Software/Control PC Issues | Imaging training, M101 galaxy. Note: Focus setting for BVR filters was 98300. Focus setting for Empty filter was 100400. Software crashed "Ace Client software not working." Rebooted to restore session. |
05/02/2021 | Javier Licandro | Instituto de Astrofísica de Canarias | Hissa Medeiros | Andor camera (JKT) | 7 | 3 | Humidity | The humidity at the beginning of the night varied between 70% and 100%. The humidity was stable after 00:00 UTC. |
05/30/2021 | Todd Hillwig | Valparaiso University | None | Andor CCD | 0 | 10 | Clouds | High humidity early followed by clouds. |
05/01/2021 | Stephen Gillam | ERAU | Savannah Caldwell, Leila Alamos, Aakash Thyigarajan, Lilyanne Pepe, Chloe Nelson Kiara Richardson | Andor CCD | 11 | 4 | Equipment Failure | ROAp stars. The dome azimuth rotation stopped working around 5 AM.
We carried out the following procedures.
1. Full ACE client restart. Three times. No joy there.
2. Azimuth recycle. Twice. It worked on the second attempt. Dome did not need homing. The first attempt likely failed because we turned OFF the recycle, then turned it on. |
04/28/2021 | Saida Caballero | FIT | Kamp | CCD | 0 | 10 | Clouds | Massive star survey |