Date | Name | Affiliation | Other Observers | Instrument | Hrs Observed | Hrs Lost | Reason | Observing Program |
|---|---|---|---|---|---|---|---|---|
08/14/2026 | Robert Berrington | Ball State University | none | arc | 0 | 10 | Clouds | Questionable night with poor transmission. Did not open. |
08/13/2026 | Aarran Shaw | Butler U | The occasional visit from my fluffiest cat | CCD | 6 | 2 | Equipment Failure | Best focus 101700, CCD imaging of CV candidates. Lost tracking at HA 02:23, didn't have backup target so closed up, parked dome at 235 and turned off the power to the dome door. I also couldn't get the autoguider to work, which wasn't a problem for my exposure times but could become one in the future. |
08/11/2026 | Tom Rutherford | ETSU | None | Andor CCD | 8 | 0.5 | Equipment Failure | Telescope stopped tracking three times during the night-- I was able to get it going gain without a restart. Delta Scuti star, M31, N Tau 2026. |
08/10/2026 | Todd Vaccaro | Ball State University | n/a | Andor | 8 | 1 | Equipment Failure | Twice as my objects hit HA of about 3 in the west the tracking stopped and I had to do a full reset to recover control. The dome does not want to track with the tele when you Z park, you have to move to an object and toggle the dome link, I don't even think parking it helped when I kept trying to get it to line up with Z park. I had to do a full reset in the middle of the night b/c the focus routine hung up as well. I also lost a batch of data b/c I didn't notice that the first 2 filters in the sequencing window were set to double bin, which I assumed were all single binned as that's how I did my bias and flat fields in the main Andor window. Toggling the CCD pc settings for time to auto sync off/on seemed to fix the 1 second offset that time.is web site was reporting, which seems to be a work around for the sync button that fails to connect to a server. I was able to see the dome was closed once enough sunrise shown through the slit and I made sure that the shutter was powered off and the dome and tele were parked. |
08/08/2026 | Martha Leake | Valdosta State University | None | CCD | 0 | 8 | Other | Dust may be the biggest reason to not open at present. Also, due to continued computer problems at SARA office at VSU, I worry that the existing computer is not able to be controlled as needed. Dusty conditions are over 20. Sunset will be within two hours (20:06 UT).. |
08/03/2026 | Roi Alonso | IAC | none | CCD | 8 | 0 | Equipment Failure | Focuser not moving. X-stage apparently not changing positions (stars the same in the images). Elongated stars E-W appearing randomly in time, probably due to RA drive vibrations. See Discord. |
08/02/2026 | Walter Van Hamme | FIU | Samec | ANDOR | 0 | 8 | Connection Issues | Unable to open dome. Must locate "Switched PDU on browser". |
08/01/2026 | Tom Rutherford | ETSU | None | CCD | 0 | 8 | Other | Dust levels high so did not open. |
08/31/2025 | Tom Rutherford | ETSU | None | CCD | 0 | 8 | Other | |
07/30/2026 | Tom Rutherford | ETSU | None | CCD | 0 | 8 | Other | Dust levels near the closing limits as well as a few high clouds so did not open. |
07/29/2026 | Tom Rutherford | ETSU | None | CCD | 0 | 8 | Other | Dust levels high all night. Unable to open. |
07/28/2026 | Billy Quarles | ETAMU | Ivan Penuelas, Alan Briseno | CCD | 6.5 | 1 | Equipment Failure | The first target was an eclipsing binary, and the second target was an exoplanet. At the beginning of the second target slewing failed at about HA = 4, stating "Unable to complete slew due to an equipment error". A full reset of ACE fixed the issue. Then later on, the same issue occurred again, and a full reset of ACE fixed the issue. After the first restart, the DIO panel was all green but the slew and dome commands were responsive. Then after the second restart, the DIO panel was normal and the mirror cover became responsive. |